http://fr.bjhygkcable.com
Accueil > Liste de Produits > Câble d’alimentation haute tension > 33kv armoured underground cable with XLPE insulated

33kv armoured underground cable with XLPE insulated

    Type de paiement: L/C,T/T,D/P,Paypal,Money Gram,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT,CIP
    Quantité de commande minimum: 1000 Meter
    Délai de livraison: 30 jours
Informations de base

Modèle: N2XSRY

Application: Centrale électrique, Industriel, Souterrain, Construction

Tension: Câble de basse et moyenne tension

Actuel: DC & AC

Matériau d'isolation: XLPE

Matériau de la gaine: Réticulation

Forme du matériau: Fil rond

Matériau du noyau: Fil de cuivre nu

Certification: VDE, UL, RoHS, CE, CCC, ISO

Brand: HUAYUAN YONGTONG

maquette: ZRYJV22

Additional Info

Détails d'emballage: Drum

productivité: 1000km/M

marque: HUAYUAN YONGTONG

transport: Ocean,Land,Air

Lieu d'origine: Beijing,China

Capacité d'approvisionnement: 1000km/M

Certificats : CE,CCC,ISO

Code SH: 8544601200

Hafen: Tianjin Port,Shanghai Port,Qingdao Port

Description du produit

Standards of 33kv armoured underground cable with XLPE insulated price

The cable is manufactured according to IEC 60502.2, IEC 60502.1, AS/NZS 1429.1, AS/NZS 5000.1, BS 6622/7835, BS 5467, BS 6746, BS 6346, VDE 0276, ASTM, ABNT etc. It is suitable to be installed in the power line with rated voltage from (U0/U)0.6/1kV to 19/33kV for power transmission.

33kv armoured underground cable with XLPE insulated

The electric cable is applied to transmit and distribute power in power transmission and distribution system of 1kV~35kV or lower. It is widely adopted in the fields including power, construction, industry, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial re-place of PVC insulation or XLPE power cable.

35kv xlpe insulated power cable


33kv armoured underground cable with XLPE insulated

Type

Description

Applications

N2XY/N2XSEY

NA2XY/NA2XSEY

Cu or AL conductor XLPE insulated PVC sheathed power cables.

For laying indoors, in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts.

N2X2Y/N2XSE2Y

NA2X2Y/NA2XSE2Y

Cu or AL conductor XLPE insulated PE sheathed power cables.

N2XBY/N2XSEBY

NA2XBY/NA2XSEBY

Cu or AL conductor XLPE insulated PVC sheathed internal steel tape armoured power cables.

For laying indoors, in tunnels, in ducts and underground. Able to bear extermal mechanical force but not large pulling forces, Impermissible to use single core cable in A.C circuit.

N2XB2Y/N2XSEB2Y

NA2XB2Y/NA2XSEB2Y

Cu or AL conductor XLPE insulated PE sheathed internal steel tape armoured power cables.

N2XRY/N2XSERY

NA2XRY/NA2XSERY

Cu or AL conductor XLPE insulated PVC sheathed internal steel wire armoured power cables.

For laying in underground areas along route with large difference of elevation, in shafts and in water, able to bear a corresponding pulling forces and external mechanical forces.

N2XR2Y/N2XSER2Y

NA2XR2Y/NA2XSER2Y

Cu or AL conductor XLPE insulated PE sheathed internal steel wire armoured power cables.

Cable Properties of 33kv armoured underground cable with XLPE insulated price

Special features which we can offer for LV and MV cables:

* Watertight construction (both radial and longitudinal).
* Resistant to heavy vibration.
* Available in long delivery lengths to reduce number of joints.
* Corrosion-free screen area.
* Copper or aluminum conductor up to 2500mm².
* Different options for outer PE jackets (LDPE, MDPE & HDPE).
* Different options for PVC, LSF, LSZH & FRPVC, being anti-termite or UV resistant as per

BS 7835, IEC 60332 etc.
* Strippable insulation screen.

* Increased armour conductivity by insertion of hard drawn copper wires in armour.

The maximum rated temperature

XLPE insulated,the maximum operating temperature of conductor shall exceed 90℃when the cable is used for long not period. The temperature of conductor shall not exceed 250℃ at short circuit for 5 seconds.

PVC insulated,the maximum operating temperature of conductor shall exceed 90℃ or 70 ℃ when the cable is used for long not period. PVC insulated the temperature of conductor shall not exceed 160℃ at short circuit for 5 seconds.

Installation requirement

The installation of cable is not limited by the difference of elevation along the route. The ambient temperature should not be below 0℃ during installation. The permissible bending radius for cable shall be complied with the following regulations:

For single-core: R>20(D+d) +/-5%

For multi-core: R>15(D+d) +/-5%

Where:R-bending radius (mm) , D-overall diameter of the cable (mm) , d-diameter of conductor (mm).

Single core cable of using in AC circuit shall be without armour or with steel wire armour and shall not be laid in magnetic ducs.

Rated voltage, No. of core and range of sectional area:

Rate Voltage(kv): 0.6/1kV 1.8/3kV 3.6/6kV 6/10kV 8.7/15kV 12/20kV

18/30kV 21/35kV

Equivalent to : 0.6/1kV 1.9/3.3kV 3.8/6.6kV 6.35/11kV 8.7/15kV 12.7/22kV

19/33kV 21/35kV

Factory and Equipment

cooper220Kv out door terminations jobsiteIMG_20160708_103155_HDRIMG_20160708_103155_HDRforeign customers in our factory


Package

cantainer

Our Honor

Product and Test Equipment

Location

Location


Groupes de Produits : Câble d’alimentation haute tension

Envoyer à ce fournisseur
  • *Sujet:
  • *Messages:
    Votre message doit comporter de 20 à 8000 caractères
Contacter le Fournisseur?fournisseur
Crazy Zhang Mr. Crazy Zhang
Que puis-je faire pour vous?
T'Chat contacter le fournisseur