http://fr.bjhygkcable.com
Accueil > Liste de Produits > Câble d’alimentation haute tension > CÂBLES D'ALIMENTATION ARMÉS EN ALLIAGE ISOLÉ À PLOMB DE 66 KV XLPE

CÂBLES D'ALIMENTATION ARMÉS EN ALLIAGE ISOLÉ À PLOMB DE 66 KV XLPE

    Type de paiement: L/C,T/T,D/P,Paypal,Money Gram,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Quantité de commande minimum: 1000 Kilometer
    Délai de livraison: 30 jours
Informations de base

Modèle: YJVQ02

Type: Isolé

Type de conducteur: Solide

Application: Souterrain

Matériau du conducteur: Cuivre

Matériau de la gaine: Réticulation

Matériau d'isolation: XLPE

Forme du matériau: Fil rond

Gamme d'application: Ignifuge

Certification: VDE, RoHS, CCC, UL, CE, ISO 9001

Brand: HUAYUAN YONGTONG

Additional Info

Détails d'emballage: Tambour

productivité: 100km/M

marque: HUAYUAN YONGTONG

transport: Ocean,Land,Air

Lieu d'origine: Pékin, Chine

Capacité d'approvisionnement: 1000km/M

Certificats : CE,CCC,ISO,KEMA

Code SH: 8544601300

Hafen: Tianjin Port,Shanghai Port,Qingdao Port

Description du produit

1. GÉNÉRAL

Cette spécification répertoriée couvre la structure, la performance, les tests et les informations d'emballage du câble d'alimentation HT.

Les questions non mentionnées dans cette spécification technique doivent être négociées par l'acheteur et le fournisseur. Ce document confirme l'accord des deux parties en tant qu'accord technique du contrat, sauf disposition contraire dans les annexes écrites officielles.

2. NORMES APPLICALBE

Le câble doit être conçu, fabriqué et testé conformément aux normes internationales suivantes:

Quality Control Standard

ISO 9001

Quality Management Systems

ISO 14001

Environmental Management Systems

Component Material Standard

IEC 60228

Conductors of insulated cables

Cable Standard

AS/ NZS 1429.2

AS/NZS 1429.2:1998 Australian/New Zealand Standard Electric cables-Polymeric insulated Part 2: For working voltages above 19/33 (36) kV up to and including 76/132 (145) kV


3 . CABLES STRUCTURE POUR 1C * 240 MM 2 C ABLE

1Cx240mm2 cable

CU / XLPE / LAS / HDPE 38/66 (72,5) kV 1 × 240 mm 2

Construction

Nominal Thickness(mm)

Nominal Diameter(mm)

1.Copper conductor

37/2.97

18.4±0.2

2.Semi-conductive  tape

0.14

19.0

3.Conductor screen (wrapping + extruding)

1.2

20.8

4.XLPE insulation

12.0

44.8(-1.5,+1.5)

5.Insulation screen

1.0

46.8

6.Semi-conductive water blocking tape

2.0

48.8

7.Lead alloy sheath

1.8

52.4

8.Anti-corrosive layer (Asphalt)

0.25

52.9

9.Outer sheath

4.0

60.9

10. Graphite coating

 

60.9±3.0

4. INFORMATIONS TECHNIQUES G UARANTEED

No

DESCRIPTION

UNIT

VALUEREQUIRED

1

Manufacturer

BEIJING HUAYUAN 

2

Cable size

mm2

240

3

Cable type

CU/XLPE/LAS/HDPE

4

Voltage Grade(U0/U(Um)

KV

38/66(72.5)

5

Reference Standard

AS/NZS 1429.2

6

No. and cross sectional area of conductor

1C 240sqmm

7

Conductor material

Copper

8

Shape

Circular compact stranded

9

Nominal diameter of conductor

mm

18.4

10

Conductor Screen materials

Simi-conduction tape + Extruded semi-conducting compound

11

Nominal thickness of conductor screen

mm

1.2(lapping +extrusion)

12

Insulation material

 

XLPE

13

Nominal thickness of insulation

mm

12.0

14

Nominal diameter over insulation

mm

44.8

15

Insulation screen material

Extruded semi-conducting compound

16

Nominal thickness of insulation screen

mm

1.0

17

Metallic Sheath

Lead alloy

18

Nominal thickness or diameter of metallic

mm

1.8

19

Short circuit current rating(t=1.0sec)

Of conductor

kA

34.3

 

Of metal sheath

kA

7.7

20

Outer sheath material

HDPE

21

Nominal thickness of outer sheath

mm

4.0

22

Nominal overall diameter of cable

mm

60.9

23

Approx. weight of cable

Kg/km

8160

24

Minimum bending radius

mm

1520

25

Max.D.C. Conductorresistanceat20`C

Ω/km

0.0754

26

Nominal capacitance per phase

uF/km

0.174

27

Max. current rating in air( temperature 35° C    and , 1 circuit ,phase spacing 1 time diameter cable, trefoil formation)

A

528(a point earthed or cross connected)

28

Max. current rating in ground(a point earthed or cross connected)

A

512 (depth of laying 1200 mm ,thermal resistivity of soil 1.2 k.m/W,25℃)

29

Max. conductor temperature on continuous

90

30

Max. conductor temperature in short circuit

250(not exceed 5s)

5. EXIGENCES D'ESSAI POUR LES CÂBLES D'ALIMENTATION HT

L'essai de câble doit être effectué conformément à la norme applicable des câbles d'alimentation de 66 kV. Les éléments d'essai suivants doivent être réalisés conformément aux normes AS 1660 pertinentes.

No.

Test item

Routine tests

1

conductor examination electrical resistance

2

Thickness of extruded screen ;projection or irregularities at conductor screen/insulation interface

3

Insulation thickness and concentricity

4

Partial discharge test

5

High voltage AC. Test for 30min

6

Spark test of non-metallic sheath

Sample tests

1

Insulation shrinkage

2

Insulation impurity determination

3

Hot set test for XLPE insulation

4

measurement of thickness of metal sheath

5

measurement of thickness of insulation and non-metallic sheath

6

Heat shock (PVC only)

6 . DONNEES 66 EMBALLAGES CABLES K VP eurs

Les câbles doivent être enroulés sur des fûts en acier non retournables. Le marquage indélébile doit être imprimé sur la surface de la bride du tambour conformément aux exigences du client.

package2package 1

Cable Type

Drum length(m)

Drum Dimensions (mm)

D

d

b

B

CU/XLPE/LAS/HDPE-38/66kV-1C*240mm2

750

2500

1600

1650

1900

Remarque: La valeur [D "ne doit pas contenir la dimen- sion des plaques d'étanchéité.




1.69kv Câble 2.Hv XLPE Câble 3.Aluminum alliage conducteur XLPE 4.Steel Fil blindé Câble blindé 5.Steel Bande 6.High Tension Câble d'alimentation

Groupes de Produits : Câble d’alimentation haute tension

Envoyer à ce fournisseur
  • *Sujet:
  • *Messages:
    Votre message doit comporter de 20 à 8000 caractères
Contacter le Fournisseur?fournisseur
Crazy Zhang Mr. Crazy Zhang
Que puis-je faire pour vous?
T'Chat contacter le fournisseur