http://fr.bjhygkcable.com
Accueil > Liste de Produits > Câble d’alimentation haute tension > 290/500 (550) kv 1x1600mm2 câble d'alimentation isolé XLPE haute tension

290/500 (550) kv 1x1600mm2 câble d'alimentation isolé XLPE haute tension

    Type de paiement: L/C,T/T,D/P,Paypal,Money Gram,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT,CIP
    Quantité de commande minimum: 1000 Bag/Bags
    Délai de livraison: 30 jours
Informations de base

Modèle: YJLW02

Type: Isolé

Type de conducteur: Échoué

Matériau du conducteur: Cuivre

Matériau de la gaine: Réticulation

Matériau d'isolation: XLPE

Forme du matériau: Fil rond

Gamme d'application: Réfractaire

Brand: HUAYUAN YONGTONG

Application: Souterrain

Additional Info

Détails d'emballage: Tambour

productivité: 1000km/M

marque: HUAYUAN YONGTONG

transport: Ocean,Land,Air

Lieu d'origine: Pékin, Chine

Capacité d'approvisionnement: 100km/M

Certificats : CE,CCC,ISO,KRMA

Code SH: 8544601900

Hafen: Tianjin Port,Shanghai Port,Beijing

Description du produit

1. GÉNÉRAL

Cette spécification énumérée couvre la structure, la performance, l'essai et les informations d'emballage du câble d'alimentation HV tel que fabriqué par Beijing Huayuan Gaoke Cable Co., Ltd.

Les questions non mentionnées dans cette spécification technique doivent être négociées par l'acheteur et le fournisseur. Ce document confirme l'accord des deux parties en tant qu'accord technique du contrat, sauf disposition contraire dans les annexes écrites officielles.

2. NORMES APPLICALBE

Le c doit être conçu, fabriqué et testé conformément aux normes internationales comme suit:

Quality Control Standard

ISO 9001

Quality Management Systems

ISO 14001

Environmental Management Systems

Component Material Standard

IEC 60228

Conductors of insulated cables

Cable Standard

IEC 62067

Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 500 kV (Um = 550 kV) - Test methods and requirements

STRUCTURE 3.CABLES POUR CÂBLE 1C * 1600 MM2

500kv 1x1600mm2


CU / XLPE / CAS / PVC 290/500 (550) kV 1 × 1600 mm2

structure

Nominal thickness

mm

Nominal diameter

mm

1 Copper Conductor(5 segmental)

/

48.7± 0.6

2 Semi-conductor tape

0.14

49.7

3 Conductor screen (wrapping +extruding)

2.5

53.7

4 XLPE insulation

32.0

117.7(-1.5,+1.5)

5 Insulation screen

1.5

120.7

6 Semi-conductor water blocking tape

2.0

129.4

7 Corrugated aluminum sheath(Welding)

3.1

149.5

8 Corrosion resistant layer (Asphalt )

0.25

150.0

9 PVC Outer jacket

6.0

162.0

10 Graphite coating

 

162.0±3.0

4. MENTIONS TECHNIQUES GARANTIES

No

DESCRIPTION

UNIT

VALUEREQUIRED

1

Manufacturer


Beijing Huayuan

2

Cable size

mm2

1600

3

Cable type


CU/XLPE/CAS/PVC

4

Voltage Grade(U0/U(Um)

KV

290/500(550)

5

Reference Standard


IEC 62067 IEC60228

6

No. and cross sectional area of conductor

 

1C 1600mm2

7

Conductor material


Copper

8

Shape


5 segmental

9

Nominal diameter of conductor

mm

48.7

10

Conductor Screen materials


Simi-conduction tape + Extruded semi-conducting compound

11

Nominal thickness of conductor screen

mm

2.5(wrapping +extrusion)

12

Insulation material

 

XLPE

13

Nominal thickness of insulation

mm

32.0

14

Nominal diameter over insulation

mm

117.7

15

Insulation screen material


Extruded semi-conducting compound

16

Nominal thickness of insulation screen

mm

1.5

17

Materials metallic Sheath


Aluminum(welding)

18

Nominal thickness of metallic sheath

mm

3.1

19

Short circuit current rating(t=1.0sec)




Of conductor

kA

230

 

Of metal screen with metal sheath

kA

142

20

Outer sheath material


PVC

21

Nominal thickness of outer sheath

mm

6.0

22

Nominal diameter of cable

mm

162.0

23

Approx. weight of cable

Kg/km

31790

24

Minimum bending radius

mm

3240

25

Max.D.C. Conductor resistanceat20`C

Ω/km

0.0113

26

Nominal capacitance per phase

uF/km

0.170

27

Max. current rating in air(a point earthed or cross connected)

A

1712( temperature 40° C , 1 circuit ,phase spacing 300, flat  formation)

28

Max. current rating in underground(a point earthed or cross connected)

A

1(temperature 40° C , depth  of laying 1200 mm ,thermal resistivity of soil 1.0 k.m/W , phase spacing 300 , flat  formation)

29

Max. current rating in direct burial(a point earthed or cross connected, temperature 35℃,1 circuit)

A

1128(temperature 25° C , depth  of laying 1500 mm ,thermal resistivity of soil 1.0 k.m/W, phase spacing  300, flat  formation)

30

Max. conductor temperature on continuous

90

31

Max. conductor temperature in short circuit

250(not exceed 5s)

5. EXIGENCES DE TEST POUR LES CÂBLES D'ALIMENTATION HT

L'essai de câble doit être effectué conformément à la norme applicable des câbles d'alimentation de 275 kV. Les éléments d'essai suivants doivent être réalisés conformément aux normes CEI pertinentes.

No.

Test item

Routine tests

1

Partial discharge test

2

Voltage test

3

electrical test on oversheath of the cable

Sample tests

1

conductor examination

2

measurement of electrical resistance of conductor and of metal screen/sheath

3

measurement of thickness of insulation and oversheath

4

measurement of thickness of metal sheath

5

measurement of diameters

6

hot set test for XLPE  insulation

7

measurement of capacitance


6. CONDITIONS D'EMBALLAGE POUR CÂBLES D'ALIMENTATION 500 KV

Les câbles doivent être enroulés sur des fûts en acier non retournables. Le marquage indélébile doit être imprimé sur la surface de la bride du tambour conformément aux exigences du client.

Drumpackage 1



Usine et équipement

power cable durm

middle voltage package1


Paquet



Honneur

Certificates


Groupes de Produits : Câble d’alimentation haute tension

Envoyer à ce fournisseur
  • *Sujet:
  • *Messages:
    Votre message doit comporter de 20 à 8000 caractères
Contacter le Fournisseur?fournisseur
Crazy Zhang Mr. Crazy Zhang
Que puis-je faire pour vous?
T'Chat contacter le fournisseur