Accueil > Liste de Produits > Câble d’alimentation haute tension > 1x1000 mm2 CABLE D'ALIMENTATION 38/66 (72.5) kV CU / XLPE / LS / CWS / HDPE

1x1000 mm2 CABLE D'ALIMENTATION 38/66 (72.5) kV CU / XLPE / LS / CWS / HDPE

    Type de paiement: L/C,T/T,Paypal,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT,CIP
    Quantité de commande minimum: 1000 Meter
    Délai de livraison: 30 jours
Informations de base

Modèle: YJQS03

Type: Isolé

Type de conducteur: Échoué

Application: Souterrain

Matériau du conducteur: Cuivre

Matériau de la gaine: Réticulation

Matériau d'isolation: XLPE

Forme du matériau: Fil rond

Certification: VDE, RoHS, CCC, UL, CE, ISO 9001

Brand: HUAYUAN YONGTONG

Gamme d'application: LSOH

Additional Info

Détails d'emballage: Tambour

productivité: 100km/M

marque: HUAYUAN YONGTONG

transport: Ocean,Land,Air

Lieu d'origine: Pékin, Chine

Capacité d'approvisionnement: 1000km/M

Certificats : CE,CCC,ISO,KEMA

Code SH: 8544601300

Hafen: TIANJIN,SHANGHIA,QINGDAO

Description du produit

1. GÉNÉRAL

Cette spécification énumérée couvre la structure, la performance, le test et les informations d'emballage de câble d'alimentation EHV tel que fabriqué par Beijing Huayuan Gaoke Cable Co., Ltd.

Les questions non mentionnées dans cette spécification technique doivent être négociées par l'acheteur et le fournisseur. Ce document confirme l'accord des deux parties en tant qu'accord technique du contrat, sauf disposition contraire dans les annexes écrites officielles.


2. NORMES APPLICALBE

Le câble proposé doit être conçu, fabriqué et testé conformément aux normes internationales suivantes:

Quality Control Standard

ISO 9001

Quality Management Systems

ISO 14001

Environmental Management Systems

Component Material Standard

IEC 60228

Conductors of insulated cables

Cable Standard

IEC 60840

Power cables with extruded insulation and their accessories for rated voltages  above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV) – Test methods and requirements

3. STRUCTURE DES CÂBLES pour le câble 66kV

cable6



CU / XLPE / LS / CWS / PEHD 38/66 (72,5) kV 1 × 1000 mm2

Structure

   Nominal thickness mm

  Nominal diameter mm

   1 Five(5) Milliken (segmental) copper conductor

/

38.8±0.6

   2 Semi-conductive tape

0.14

39.4

   3 Conductor screen(wrapping & extruding)

2.0

42.8

   4 XLPE insulation

12.0

66.8±1.5

   5 Insulation screen

1.0

68.8

   6 semi-conductive water blocking tape

2.0

70.8

   7 lead sheath

3.0

76.8

   8 Semi-conductive water blocking tape

2.0

78.8

   9 Copper wire screen with  

c    opper tape wrapping(gap)

       Nominal sectional area 120.0mm2

81.8

   10 non-conductive water blocking tape

0.6

82.8

   11 HDPE outer sheath

4.5

91.8

   12 semi-conductive layer(extruding)

0.5

92.8±3.0

La gaine de Leas avec le fil de cuivre entreprennent le courant de court-circuit de charge ensemble



4. Caractéristiques techniques garanties

No

DESCRIPTION

UNIT

VALUEREQUIRED

1

Manufacturer



Beijing Huayuan Gaoke Cable.Co.,Ltd.


2

Cable size

mm2

1000(nominal)

3

Cable type


CU/XLPE/LS/CWS/HDPE

4

Voltage Grade(U0/U(Um)

KV

38/66(72.5)

5

Reference Standard


IEC 60840

6

No. and cross sectional area of conductor


1C 1000sqmm

7

Conductor material


Copper

8

Shape


Five(5) Milliken (segmental)

9

Nominal diameter of conductor

mm

38.8

10

Conductor Screen materials


Simi-conduction tape + Extruded semi-conducting compound

11

Nominal thickness of conductor screen

mm

2.0(wrapping + extruding)

12

Insulation material

 

super clean XLPE

13

Nominal thickness of insulation

mm

12.0

14

Nominal diameter over insulation

mm

66.8

15

Insulation screen material


Extruded semi-conducting compound

16

Nominal thickness of insulation screen

mm

1.0

17

Metallic Screen material


copper wire with copper tape binder tape (gap)

18

Short circuit current rating(t=1.0sec)




Of conductor

kA

144


Of metallic screen

kA

≥25(lead sheath with copper wire)

19

Outer sheath material


HDPE

 

Colour

 

yellow

20

Nominal thickness of outer sheath

mm

4.5

21

Nominal thickness of extrude semi-conductive layer

mm

0.5

22

Nominal overall diameter of cable

mm

92.8

23

Approx. weight of cable

kg/km

21860

24

Minimum bending radius

mm

2320

25

Max.D.C. Conductor resistance at20`C

Ω/km

0.0176

26

Nominal capacitance per phase

uF/km

0.30

27

Max. current rating in air at  40° C

A

1442(1 circuit ,phase spacing  250, flat formation, a point earthed or cross connected)

28

Max. current rating in ground at 25° C

A

1273circuit ,phase spacing  250, flat formation, a point earthed or cross connected ,depth of laying 1200 mm ,thermal resistivity of soil 1.0 k.m/W)

29

Max. conductor temperature on continuous

90

30

Max. conductor temperature in short circuit

250(not exceed 5s)

5. EXIGENCES D'ESSAI POUR les câbles d'alimentation EHV

L'essai de câble doit être effectué conformément à la norme applicable des câbles d'alimentation de 66 kV. Les éléments d'essai suivants doivent être réalisés conformément aux normes CEI pertinentes.

No.

Test item

Routine tests

1

Partial discharge test

2

Voltage test

3

electrical test on oversheath of the cable

Sample tests

1

conductor examination

2

measurement of electrical resistance of conductor and of metal screen/sheath

3

measurement of thickness of insulation and oversheath

4

measurement of thickness of metal sheath

5

measurement of diameters

6

hot set test for XLPE  insulation

7

measurement of capacitance


Compagnie

undefined


Atelier

undefined

Paquet

undefinedundefined


Livraison et paiement

undefined

undefined

Honneur

undefined

Client

undefined



Groupes de Produits : Câble d’alimentation haute tension

Envoyer à ce fournisseur
  • *Sujet:
  • *Messages:
    Votre message doit comporter de 20 à 8000 caractères
Contacter le Fournisseur?fournisseur
Crazy Zhang Mr. Crazy Zhang
Que puis-je faire pour vous?
T'Chat contacter le fournisseur